Regulations and standards
49
5. Installing and wiring in compliance with EMC Directive
This product has been designed and manufactured to be incorporated in equipment. The EMC Directive requires that your
mechanical equipment in which the product is installed satises the applicable requirements.
The installation and wiring methods of the motor and driver explained here represent the basic methods that are eective in
helping your mechanical equipment conform to the EMC Directive.
The nal level of conformance of your mechanical equipment to the EMC Directive will vary depending on such factors as
the control system equipment used with the motor/driver, conguration of electrical parts, wiring, layout and hazard level. It
therefore must be veried through conducting EMC measures on your mechanical equipment.
Without eective measures to suppress the electromagnetic interference (EMI) caused by the product in the surrounding control
system equipment or the electromagnetic spectrum (EMS) generated by the product, the function of your mechanical equipment
may be seriously aected.
The use of the following installation and wiring methods will enable this product to be compliant with the EMC directive.
Connecting a mains lter
Install a mains lter which the customer provides, in the power line in order to prevent the noise generated within the driver from
propagating outside via the AC input line. For a mains lter, use the products as shown in the table, or an equivalent.
Manufacturer
Single-phase 100-120 VAC
Single-phase 200-240 VAC
Three-phase 200-240 VAC
Soshin Electric Co., Ltd. HF2010A-UPF, NF2010A-UP HF3010C-SZA, NFU3010C-Z1
Schaner EMC FN2070-10-06 FN3025HP-10-71
Overvoltage category II applies to mains lters.
Install the mains lter as close to the driver as possible.
Use cable clamps and other means to secure the input and output cables rmly to the surface of the enclosure.
Connect the ground terminal of the mains lter to the grounding point, using as thick and short a wire as possible.
Do not place the AC input cable (AWG18 to 14: 0.75 to 2.0 mm
2
) parallel with the mains-lter output cable (AWG18 to 14: 0.75
to 2.0 mm
2
). Parallel placement will reduce mains lter eectiveness if the enclosures internal noise is directly coupled to the
power supply cable by means of stray capacitance.
Connecting an external power supply
Use an external power supply conforming to the EMC Directive. Use a shielded cable to wire the external power supply over the
shortest possible distance. Refer to "Wiring the power supply cable" for how to ground the shielded cable.
How to ground
The cable used to ground the motor, driver, mains lter and power supply cable (shielded cable) must be as thick and short
as possible so that no potential dierence is generated among the grounding points. Choose a large, thick and uniformly
conductive surface for the grounding point. Refer to the p.16 for the recommended grounding method.
Wiring of the power supply cable
Use a shielded cable of AWG18 to 14 (0.75 to 2.0 mm
2
) in diameter for the power supply cable and keep it as short as possible.
Strip a part of the shielded cable and ground the stripped part using a metal cable clamp that contacts the stripped cable around
its entire circumference, or use a drain wire to make the ground connection.
Connect both ends (mains lter side and power supply side) of the shielded cable to the grounding points so that no potential
dierence is generated between grounds.
Cable clamp
Shielded cable
Notes about installation and wiring
Connect the motor, driver and other peripheral control equipment directly to the grounding point so as to prevent a potential
dierence from developing between grounds.
When relays or electromagnetic switches are used together with the product, use mains lters or CR circuits to suppress surges
generated by them.
Keep cables as short as possible without coiling and bundling extra lengths.
Wire the power lines such as the connection cable and power supply cable away from the signal cables by providing a
minimum clearance of 100 mm (3.94 in.) between them. If they must cross, do so at a right angle.
Place the AC input cable and output cable of a mains lter separately from each other.
Use a dedicated connection cable (sold separately) for the connection between the motor and driver.
The EMC measures are conducted using the Oriental Motor connection cable.