7
General specications
Operating
environment
Ambient
temperature
0 to +50 °C [+32 to +122 °F] (non-freezing)
Ambient
humidity
85% or less (non-condensing)
Altitude Up to 1000 m (3300 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust.
Cannot be used in radioactive materials,
magnetic eld, vacuum or other special
environment.
Vibration
Not subject to continuous vibrations or excessive
impact.
In conformance with JIS C 60068-2-6 "Sine-wave
vibration test method"
Frequency range: 10 to 55 Hz,
Pulsating amplitude: 0.15 mm
Sweep direction: 3 directions (X, Y, Z),
Number of sweeps: 20 times
Storage
environment
Shipping
environment
Ambient
temperature
−25 to +70 °C [−13 to +158 °F] (non-freezing)
Ambient
humidity
85% or less (non-condensing)
Altitude Up to 3000 m (10000 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water or oil.
Cannot be used in radioactive materials,
magnetic eld, vacuum or other special
environment.
Degree of protection
IP65
(Excluding the mounting surface of the round
shaft type and connectors)
Lead wire type : IP40
Regulations and standards
UL Standards, CSA Standards
This product is recognized by UL under the UL and CSA Standards.
The motor model name represents the model that conforms to the standards.
Output power Applicable standards
Certication
body
File No.
15 W, 30 W, 50 W
UL 62368-1
CSA C22.2 No.62368-1
UL E208200
100 W
UL 60950-1
CSA C22.2 No.60950-1
Thermal class UL/CSA Standards: 105(A)
CE Marking
This product is axed the CE Marking under the EN Standard.
z
Low Voltage Directive
This product is not subject to the coverage of the Low Voltage Directive
because the input power supply voltage is 24 VDC.
When conforming the equipment incorporating this product to the Low
Voltage Directive, connect the driver power supply input to the DC power
supply where the primary and secondary sides are provided with reinforced
insulation.
Install this product inside an enclosure because it is designed and
manufactured to be incorporated in equipment.
Applicable standards
EN 61000-6-4, EN 55011, EN 61000-6-2
Installation conditions (EN Standard)
To be incorporated in equipment.
Overvoltage category:
Ⅰ
Pollution degree:
Ⅱ
Protection against electric shock: Class
Ⅲ
equipment
Thermal class EN Standards: 120 (E)
z
Motor temperature rise tests
The temperature rise tests stipulated in the standards are conducted in a state
where a motor is mounted on a heat radiation plate instead of attaching a
gearhead. The size, thickness and material of the heat radiation plates are as
follows.
Motor model Size [mm (in.)] Thickness [mm (in.)] Material
BLHM230
115×115 (4.53×4.53)
5 (0.20) Aluminum alloy
BLHM450
135×135 (5.31×5.31)
BLHM5100
200×200 (7.87×7.87)
RoHS Directive
The products do not contain the substances exceeding the restriction values of
RoHS Directive (2011/65/EU).