3
z
Electromagnetic brake type
Combination type parallel shaft gearhead
Unit model Motor model
Gearhead
model
Driver model
BLV620KM
S-
BLVM620KM-GFS
GFS6G
BLVD20KM
BLV640NM
S-
BLVM640NM-GFS BLVD40NM
Combination type hollow shaft at gearhead
Unit model Motor model
Gearhead
model
Driver model
BLV620KM
F-
BLVM620KM-GFS
GFS6G
FR
BLVD20KM
BLV640NM
F-
BLVM640NM-GFS BLVD40NM
Round shaft type
Unit model Motor model Driver model
BLV620KMA-
BLVM620KM-A BLVD20KM
BLV640NMA-
BLVM640NM-A BLVD40NM
Names and functions of parts
z
Driver
Basic function switch
(SW1)
I/O signal connector [CN4]
POWER LED (Green)
ALARM LED (Red)
C-DAT LED (Green)
C-ERR LED (Red)
Internal potentiometer (VR1)
Acceleration/deceleration
time potentiometer (VR2)
Motor signal connector
[CN3]
Motor power connector
[CN2]
Main power supply input
terminal [CN1]
Electromagnetic brake
connector [CN8]
Communication
connector [CN7]
RS-485 communication
connector [CN5/CN6]
Control power supply
input terminal (TB1)
Address number setting
switch (SW3)
switch (SW2)
Mounting hole
(4 locations)
Torque limiting
potentiometer (VR3)
Name Description
POWER LED (Green)
This LED lit while the main power or
control power is input.
ALARM LED (Red)
This LED will blink when an alarm
generates (a protective function is
triggered). You can check the generated
alarm by counting the number of times the
LED blinks.
Internal potentiometer
(VR1)
Set the motor rotation speed.
Acceleration/
deceleration time
potentiometer (VR2)
Set the acceleration time and deceleration
time for the motor.
Torque limiting
potentiometer (VR3)
Set the torque limiting value of the motor.
Main power supply input
terminal [CN1]
Connect the main power supply.
BLV620
: +24 V,
BLV640
: +48 V
Motor power connector
[CN2]
Connect the motor power connector.
Motor signal connector
[CN3]
Connect the motor signal connector.
Electromagnetic brake
connector [CN8]
Connect the electromagnetic brake
connector.
Name Description
I/O signal connector
[CN4]
Use this connector when using an external
control device (programmable controller)
or inputting a operation command.
Basic function switches
(SW1)
Select the setting of the speed response,
external DC voltage and sink logic/source
logic.
Communication
connector [CN7]
Connect the
MEXE02
or
OPX-2A
.
Control power supply
input terminal
(TB1)
Connect the driver control power supply.
RS-485 communication
connector
[CN5/CN6]
Connect the RS-485 communication
cable.
C-DAT LED (Green)
This LED will illuminate when the driver
is communicating with the master station
properly via RS-485 communication.
C-ERR LED (Red)
This LED will illuminate when a RS-485
communication error occurs with the
master station.
Communication function
switch
(SW2)
Set the transmission rate, communication
protocol and termination resistor of
RS-485 communication.
Address number setting
switch
(SW3)
This switch set the address number (slave
address) of RS-485 communication.
Mounting hole
(4 locations)
4 locations on the back surface and side
surface
Uses when controlling the system via RS-485 communication.
z
Motor
Illustration shows electromagnetic brake type.
Motor cable
Motor signal connecto
Electromagnetic brake
connector
Pilot section
Motor
Electromagnetic brake
Output shaft
Mounting hole
(4 locations)
Installation
Location for installation
The motor and driver are designed and manufactured for installation in
equipment. Install them in a well-ventilated location that provides easy access
for inspection. The location must also satisfy the following conditions:
Inside an enclosure that is installed indoors (provide vent holes)
Operating ambient temperature
Motor: 0 to +40 °C [+32 to 104 °F] (non-freezing)
Driver: 0 to +40 °C [+32 to 104 °F] (non-freezing)
Operating ambient humidity 85% or less (non-condensing)
Area not exposed to direct sun
Area free of excessive amount of dust, iron particles or the like
Area free of excessive salt
Area that is free of explosive atmosphere or toxic gas (such as sulfuric gas)
or liquid
Area not subject to splashing water (rain, water droplets), oil (oil droplets)
or other liquids
Area not subject to continuous vibration or excessive shocks
Area free of excessive electromagnetic noise (from welders, power
machinery, etc.)
Area free of radioactive materials, magnetic elds or vacuum
Altitude Up to 1000 m (3300 ft.) above sea level