6
z
Combination type hollow shaft at gearhead
Gear ratio
Distance from gearhead mounting
surface and permissible radial load
[N (lb.)]
Permissible
axial load
[N (lb.)]
10 mm (0.39 in.) 20 mm (0.79 in.)
5 (
BLV640
only)
1230 (270)
<1130 (250)>
1070 (240)
<990 (220)>
800 (180)
10
15, 20
1680 (370)
<1550 (340)>
1470 (330)
<1360 (300)>
30 to 100
2040 (450)
<1900 (420)>
1780 (400)
<1660 (370)>
The values assume a rated speed of 3000 r/min or below.
The values in < > are based on a rated speed of 4000 r/min.
z
Round shaft type
Distance from tip of motor output shaft
and permissible radial load [N (lb.)]
Permissible axial load
[N (lb.)]
10 mm (0.39 in.) 20 mm (0.79 in.)
197 (44) 221 (49) 25 (5.6)
Installing the driver
The driver is designed so that heat is dissipated via air convection and
conduction through the enclosure. Install the driver on a at metal plate
having excellent vibration resistance and heat conductivity.
When two or more drivers are to be installed side by side, provide 20 mm (0.79
in.) and 25 mm (0.98 in.) clearances in the horizontal and vertical directions,
respectively.
Note
Install the driver in an enclosure whose pollution degree is
2 or better environment, or whose degree of protection is
IP54 minimum.
Do not cover the radiation vent of the driver.
Do not install any equipment that generates a large
amount of heat or noise near the driver.
If the ambient temperature of the driver exceeds 40 °C
(104 °F), revise the ventilation condition or force-cool the
area around the driver using a fan.
z
Mounting to DIN rail
When mounting the driver to a DIN rail, use the DIN rail mounting plate
PADP03
(sold separately) and attach it to a 35 mm (1.38 in.) wide DIN
rail. After installation, x the both sides of the driver with the end plate (not
included).
DIN rail
DIN lever
Hook
Mounting screw (included)
Tightening torque: 0.3 to 0.4 N·m (2.6 to 3.5 lb-in)
Mounting hole
(M3-4 locations)
Note
Do not use the mounting holes (M3, four locations) for
the DIN rail mounting plate for any purpose other than
securing the DIN rail mounting plate.
Be sure to use the included screws when securing the
DIN rail mounting plate. The use of screws that would
penetrate 3 mm (0.12 in.) or more through the surface of
the driver may cause damage to the driver.
z
Installing with screws
Ax the driver through the mounting holes using two screws (M4: not included).
When mounting in vertical direction [Unit: mm (in.)]
147 (5.79)
147 (5.79)
Ø4.5
(0.177)
2ר4.5
(0.177)
• When using
side surface A
• When using
side surface B
B
When mounting in horizontal direction [Unit: mm (in.)]
147 (5.79)
147 (5.79)
Ø4.5 (0.177)
2ר4.5 (0.177)
• When using side surface A
• When using side surface B
A
B
Setting
Basic function switch (SW1)
Address number setting
switch (SW3)
Communication function
switch (SW2)
Basic function (SW1)
SW1 Description Setting range
1 Speed response
ON: High response mode
OFF: Regenerative power suppression
mode (Factory setting)
2 External DC voltage
ON: 0 to 10 V
OFF: 0 to 5 V (Factory setting)
3
Sink logic/Source
logic
ON: Source logic
OFF: Sink logic (Factory setting)
Communication function (SW2)
Set when controlling the system via RS-485 communication.
SW2 Description Factory setting
1
Transmission rate
OFF
2
3
4 Not used
5 Communication protocol
6 Not used
7 Termination resistor
8 Extending the address number
Address number setting (SW3)
Set the address number using the SW3 and No. 8 of the communication
function switch (SW2).
Factory setting : 0