Step 5: Wiring of the unit
Remove the wire clip; connect the power connection wire and signal control wire to the wiring
terminal according to the color; fix them with screws.
Outdoor unit connection
Indoor unit connection
1
1
1
-
-
9K-12K:
1
1
1
-
Indoor unit connection
-
18K-24K:
Note: this wiring diagram is for reference only, please always refer to the one on the actual unit.
Fix the power connection wire and signal control wire with wire clip.
Notes:
After tightening the screw, pull the power cord slightly to check if it is solid.
Never cut the power connection wire to extend or shorten it.
Step 6: Pipe arrangement
The pipes should be placed along the wall, slightly
bent and if possible be hidden. The minimum
bending semi diameter is 10 cm.
If the outdoor unit is higher than the wall hole,
you must set a U-shaped curve in the pipe before
pipe goes into the house, in order to prevent rain
from getting in.
U-shaped curve
wall
drain hose