LEGEND
Icon(s) Description
G
G
B
A
C
D
E
G
H
F
J
I
K
L
M
N
Backup
D
N
D E
G
HF
J
A B C
L
Grid Tied
D
I K
M
D E
G
F
A B C
N
A B C
D E
G
H
D
F J
L
J
Off Grid
Basic Navigation
Soft Keys
Four “soft” keys are located directly below the display. Soft key functions will vary depending on the location. These
functions are identified by icons or text directly above the key. Occasionally not all four soft keys are used.
o In all cases where displayed, the <Back> soft key returns to the previous screen. The <Port> soft key cycles through each device
connected to the network. When a specific port is selected, the device on that port can be individually programmed with whatever
options are available. (Programming is often global unless assigned to a particular port.) Other soft keys are described as appropriate.
Home Screen Soft Keys
See the following pages for displays and descriptions.
 The <Charge Controller> soft key (O) displays information on all FLEXmax charge
controllers. If no controllers are detected by the HUB Communications Manager, Q is
inoperative. (The symbol and meter bar are not present.) See page 14.
 The <Battery> soft key (P) displays information on the battery bank. The information
available depends on whether the FLEXnet DC battery monitor is installed. See page 12.
 The <Inverter> soft key (Q) displays information on any inverters present on the HUB.
If no inverters are present, Q is inoperative. (The symbol is not present.) See page 8.
 For FX-class inverters: In the Off Grid system type, R is <Input Select>. It may not have
a symbol. The symbol only appears if a generator is running. (See J.) In Grid Tied,
R is <Grid Status>. will appear. In Backup, R is inoperative. See page 8.
 In the Off Grid system type: For FXR-class inverters, S is the <Input Select> soft key. For Radian-class inverters, S is the
<Input Priority> soft key. It may not have a symbol. The symbol only appears if a generator is running. (See J.)
For both FXR- and Radian-class: In Grid Tied or Off Grid, S is the <Grid Status> soft key. will appear. See page 8.
Meter Bar or Metering Notes
 In the Off Grid or Backup system types:
“OK” is replaced with ! (with an event
message) during a generator fault.
 In the Grid Tied system type: “OK” is
replaced with ! (with an event message)
during a grid fault.
 In any system type:
 “OK” is replaced with ! or X
(w
ith an event message) if the FN-DC is
present and registers a battery problem.
 “OK” is replaced with ! (with an
event message) during an inverter fault.
In the Backup system type, the
System Information menu must have
an AC generator selected. Otherwise this
field is blank. (See the MATE3s
Programming Guide.)
If Gen Type is set to DC, then the left meter
bar is scaled according to the Max Inverter
kW setting.
A
J
L
O P Q R
SO P Q
G
G
Page 6
Home Screen Legend
900-0124-12-01 Rev A
©2017 OutBack Power Technologies. All Rights Reserved.
Page 7
Soft Keys

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the OutBack Power MATE3s and is the answer not in the manual?

OutBack Power MATE3s Specifications

General IconGeneral
BrandOutBack Power
ModelMATE3s
CategoryController
LanguageEnglish

Related product manuals