7.Technical Specifications
25
be over 30 seconds.
[3]
When measuring frequency, the typical waveform is Square or Sine. The signal meets
the following conditions.
Frequency
Amplitude (rms)
1 Hz – 4 MHz
≥ 100 mV
4 M – 8 M
≥ 200 mV
8 M – 10 M
≥ 300 mV
[4]
When measuring duty cycle, the typical waveform is Square or Sine.
Display
6000
Frequency Response (Hz)
(40 - 400) Hz
Sample rate for digital data
3 times/second
Sample rate for analog bar graph
30 times/second
Bluetooth
B35(T) √
D35(T)
Without
Auto ranging
√
True RMS
The model with "T" has this function.
Diodes Test
√
Measuring Transistor
√
Sleep Mode
√
Continuity Test
√
Low battery indication
√(The " " is displayed when the battery
is under the proper operation range.)
Data Hold
√
Relative Measurement
√
MAX/MIN Value
√
LCD Backlight
√
Analog bar graph
61 Segments
Input Protection
√
Input Impedance
10 MΩ
Battery
3 V (1.5 V × 2) AA alkaline batteries
LCD Size
69 mm * 52 mm
Weight (without package)
0.32 kg
Dimension
85 mm * 185 mm * 30 mm
Working temperature
0
℃
to 40
℃
Storage temperature
-
10
℃
to 60
℃
Relative Humidity
≤ 80%
Altitude
Operating: 3,000 m
Non-operating: 15,000 m
Interval Period of Adjustment: