15
Error list TC166
62
Subject to change without notice
Error
nr.
Conditions In- /
Output
Description Possible Causes
40 Machine Start
Packing cycle
Stop-Reset-Start
B17 Time for moving out ejectors exceeded 1. Package jam in front of the ejector
2. Air pressure
3. Cylinder, cylinder switch
4. Sensor B17 defective
5. Input IN01.13 problem
6. Throttle D1 defective
7. Elevation table's lowest position set too low
41 Machine Start
Normal position
B16
B1
Machine goes into normal position and table does not
go up
1. Air pressure
2. Cylinder, cylinder switch ejector
3. Sensor B16 defective or wrongly adjusted
4. Sensor B1 defective
5. Input IN03.1 problem
42 Machine Start
Band End
B13 After "band end" has been shown on the display, the
machine switches off after the pre-programmed
number of cycles has been reached
1. Change tapes
2. Change quantity of cycles with code 127
3. Cable defective
4. Input IN03.4 problem
48
B16
Elevation table moves down
B16 is not covered
1. Package jam in front of the ejector
2. Air pressure
3. Cylinder, cylinder switch
49
B16
B1
Elevation table moves up
B16 or B1 are not covered
1. Package jam in front of the ejector
2. Air pressure
3. Cylinder, cylinder switch