Code list TC166
13
Subject to change without notice
51
13 Code list TC166
Code
nr.
Password
protected
Set
value
Unit Title Description
100 no Password 1021
102 Program version
103 no 45 1/100 sec Heating time paper Heating time for paper banding
104 no 150 1/100 sec Cooling time paper Cooling time for paper banding
105 Cycle counter
106 yes 40 1/100 sec Heating delay Delay in heating (Y17) depends on B2
108 yes 0 1/100 sec Delay 1 Delay in moving elevation table up (Y18) after reaching intermediate position (B18)
109 yes 0 1/100 sec Delay 2 Delay in moving elevation table up (Y18) after ejecting the banded parcels depends on B16
110 yes 100 1/100 sec Delay 3 After completing a package cycle, the machine only goes to destacking mode after this
length of time
111 no 4 2,35mm Tolerance Tolerance depends on calibrated value
112 no 250 1,00mm Direction counter 1 In stream feeding mode, the stream is gathered together for this length after reaching the
pre-selected batch piece value
113 no 130 1,00mm Direction counter 2 After reaching the pre-selected batch piece value the elevation table, in stream delivery
mode, only moves to the intermediate position after this value has elapsed
114 no 80 1,00mm Direction counter 3 After reaching the pre-selected batch piece value the elevation table, in single sheet mode,
only moves to the intermediate position after this value has elapsed
115 yes 100 1/100 sec Delay 4 Photocell B19 must be continuously covered for this length of time so that the elevation
table is destacking.
116 yes 50 in % of the
sheet length
Direction counter 5 In stream delivery mode, this is the maximum the belts move the sheet forward as it
arrives. The distance is calculated from the calibrated value. Standard value is 50% of the
calibrated sheet length.
117 yes 100 1/100 sec Delay5 Compensation for t he reaction of the deflector
118 yes 115 1,00mm Direction counter 6 In stream delivery mode, the start is triggered by photocells B8/B9/B11. The transport belts
start after this value has elapsed
BA700