INF-14
5-3-1. Setting item for LISTA Measurement
ATF GAIN
The speed of the tape changes if this item set to “ON” for the ATF sensitivity confirmation.
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the
menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU button is pressed in this condition.
LINEARITY
The ATF sensitivity changes if this item set to “ON” for the LINEARITY confirmation.
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the
menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed.
NOW SERVO ADJUST
PUSH MENU TO RETURN
It will be returned to ADJUST MENU when the MENU button is pressed in this condition.
Press MENU button.
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER
NOW SERVO ADJUST
PUSH MENU TO RETURN
(Adjustment mode screen)
ADJUST MENU
ATF GAIN OFF
LINEARITY OFF
AUDIO FILTER ON
Y LEVEL 1B
C LEVEL 27
DEBUG DISP OFF
DEBUG MODE OFF
LCD OFFSET OFF
PUSH MENU TO EXIT
OFF
ON

Table of Contents

Related product manuals