INF-18
Focus control voltage (V)
FOCUS
7-2. FOCUS/IRIS REMOTE
Please refer to below indicated specification, When external remote is checked.
Terminal (refer to figure A) Contents
A GND
B FOCUS control input
C IRIS control input
D IRIS(AUTO/MANU) switch input
Equivalent circuit of FOCUS/IRIS REMOTE jack
Figure C
7-2-1. Focus control input
With the voltage to input to the B terminal, the focus is changes. As for the relation between the focus control
voltage and the focus, it is as shown in the following.
Relation between the focus control voltage and focus
Figure D
When terminal B is open, the focus remote control becomes invalid.
0 0.5
1.0 1.5 2.0
0 10k 20k
NEAR
FAR
NOTE:
The control voltage and the
focus, which are shown below
are a reference value. Because
there is a little difference, see
as the reference data.
4-pole / 3.5mm diameter