Operation Details
2) Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote
Control, and then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan operates with SLo speed.
Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan
Stop for 6 minutes.
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during
compressor stops.)
When Automatic Fan Speed is selected at Remote Control during Soft Dry Operation.
Fan speed rotates at SLo speed.
Deodorizing Control.
Time Delay Safety Control
Anti-Freezing Control
Indoor
Fan
COMP
stop stop
stop
SLo
SLo
SLo
ON ON
OFF
40" 40"6'
Automatic Fan Speed Mode