– 33 –
MAC9512086C2
CS-A73KE
Shaft Position
Closed
(With valve cap)
Closed
(Clockwise)
Open
(With valve cap)
Open
(Counter-clockwise)
Open
Open
Open
Open
2-way Valve (Liquid Side)
3-way Valve (Gas Side)
Works
Shipping
Evacuation
Installation and
Re-installation
Operation
Pumping down
(Transferring)
Evacuation
(Servicing)
Gas charging
(Servicing)
Pressure check
(Servicing)
Gas releasing
(Servicing)
Shaft Position
Close
(With valve cap)
Closed
(Counter-Clockwise)
Open
(With valve cap)
Closed
(Clockwise)
Open
Open
Open
Open
Open position
Closed position
2-way 3-way Valve
To outdoor unit
To outdoor unit
Valve cap
Service
port cap
Service port
Pin
To
piping
connection
Flare nut
To
piping
connection
Open position
Closed position
Hexagonal wrench (4 mm)
Flare nut
Service Port
Closed
(With cap)
Open
(Push-pin)
Closed
(With cap)
Open
(Connected manifold
gauge)
Open
With vacuum pump
Open
(With charging cylinder)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Untitled-13 6/19/00, 11:15 AM33