11
Indoor CS-A28MKD
Model
Outdoor CU-A28MKD
Performance Test Condition NEW JIS
Phase, Hz Single, 50
Power Supply
V 220 230
kW 8.00 8.00
BTU/h 27300 27300
Capacity
kJ/h 28800 28800
Running Current A 13.2 12.7
Input Power W 2.86k 2.88k
W/W 2.80 2.78
EER
Btu/hW 9.55 9.48
Power Factor % 98 99
dB-A 49 / 44
Indoor Noise (H / L)
Power Level dB 65 / -
dB-A 55 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 70 / -
kW 8.80 8.80
BTU/h 30000 30000
Capacity
kJ/h 31680 31680
Running Current A 13.1 12.6
Input Power W 2.84k 2.86k
W/W 3.10 3.08
EER
Btu/hW 10.56 10.49
Power Factor % 99 99
dB-A 48 / 44
Indoor Noise (H / L)
Power Level dB 64 / -
dB-A 55 / -
Heating
Outdoor Noise (H / L)
Power Level dB 71 / -
Max Current (A) / Max Input Power (W) 16.4 / 3.45k
Starting Current (A) 40
Type Hermetic motor
Motor Type Induction (2 poles)
Compressor
Output Power W 2.4k
Type Cross-Flow Fan
Material ASG30K1
Motor Type Transistor (8 poles)
Input Power W 94.8 - 94.8
Output Power W 40
QLo rpm
Cooling: 1160
Heating: 1160
Lo rpm
Cooling: 1250
Heating: 1330
Me rpm
Cooling: 1380
Heating: 1380
Hi rpm
Cooling: 1500
Heating: 1540
Indoor Fan
Speed
SHi rpm Cooling: 1540