For CS-A18MKD, CS-A24MKD and CS-A28MKD 
 
 
 
 
 
 
 
 
 
 
 
 
12.8  Horizontal Airflow Direction Control 
12.8.1  Auto Control  
•  When the horizontal airflow direction is set to Auto using the remote control, the vanes swings left and right as 
shown in the diagram. 
•  When stopped with remote control, the discharge vane is reset, and stop at the reset position. 
•  During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that 
condition,  the vane will stop swinging and rest at face front position. 
•  During Heating operation, the piping air temperature reaches 38°C, the vanes swings left and right. When the 
piping air temperature falls to 35°C, the vanes will stop swing and rest at face front position. 
 
      For CS-A9MK and CS-A12MK                          For CS-A18MK, CS-A24MK and CS-A28MK 
 
   
12.8.2 Manual Control 
•  When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released 
and the airflow direction vane move left and right in the range shown in the diagram. 
•  The louver can be adjusted by pressing the button to the desired vane position. 
•  When stopped with remote control, the vanes is reset and stopped at reset position.  
 
For CS- A9MK and CS-A12MK 
 
Pattern  1 2 3 4 5 
Airflow Direction Patterns of Remote Control 
         
Vane Angle (°)  30°  60°  45°  15°  0° 
 
For CS-A18MK, CS-A24MK and CS-A28MK 
 
Pattern  1 2 3 4 5 
Airflow Direction Patterns of Remote Control 
         
Vane Angle (°)  26°  52°  39°  13°  0° 
Closing 
position  
/ 148° 
Lower limit for heating mode
Horizontal 
17° 
27° 
42° 
33° 
52° 
Upper limit for 
heating mode