55 
•  The operation mode judging temperature and standard setting temperature can be increased by 2°C 
permanently, by open the circuit of JX03 at indoor unit’s printed circuit board. 
 
 
12.5  Indoor Fan Speed Control 
•  Indoor fan speed can be set using remote control. 
12.5.1  Fan Speed Rotation Chart 
 
Fan Speed (rpm)  CS-A9MKD  CS-A12MKD 
SHi 1080 1120 
Hi 1040 1100 
Me 870 950 
HLo 770 840 
CLo 730 800 
Lo- 690 760 
SLo 670 740 
SSLo 300  300 
QSHi 1010 1050 
QHi 970 1030 
QMe 800  880 
QHLo 700  770 
QLo 660 730 
 
Fan Speed (rpm)  CS-A18MKD  CS-A24MKD  CS-A28MKD 
SHi 1310 1530 1540 
Hi 1240 1390 1500 
Me 1140 1270 1380 
HLo 1100 1230 1330 
CLo 1040 1150 1250 
Lo- 850 940 1030 
SLo 650 720 810 
SSLo 300 300 300 
QSHi 1220 1440 1450 
QHi 1150 1300 1410 
QMe 1050 1180 1290 
QHLo 950 1060 1160 
QLo 950 1060 1160