17.5.20 F11 (4-way Valve Switching Failure)
Malfunction Decision Conditions
When indoor heat exchanger is cold during heating (except deice) or when indoor heat exchanger is hot during
cooling and compressor operating, the 4-way valve is detected as malfunction.
Malfunction Caused
Indoor heat exchanger (pipe) thermistor
4-way valve malfunction
Troubleshooting
* Check gas side pipe – for hot gas flow in cooling mode
YES
YES
YES
NO
NO, it happen in cooling/dry as well
NO
Outdoor PCB fault
No
Good
Reconnect CN-HOT
No
Good
Attach and screw the V-coil
No
continuity
(open)
Remove CN-HOT.
V-coil fault
Reverse solenoid valve faulty
Outdoor PCB fault
No supply
OK
OK
OK
When abnormality starts again
Check the indoor pipe temperature
The 4-way valve may have been damaged
Check connecting tubes to 4-way valve
Is the measured resistance of the indoor
Problem occurs in heating mode only?
Defect in indoor pipe temperature
Is 4-way solenoid valve being energised?
4-way valve not working
Check CN-HOT
Check V-coil attach to
Check valve v-coil
Measure voltage
For safety reason and to prevent component
breakdown, always switch off the power before
remove and connect the component.
OK (Depending on 4-way valve model)
YELLOW
2
1
COIL COMPLETE
CN-HOT
(WHT)
YELLOW
4 WAYS VALVE
CN-HOT
(VH9-2)
4 WAYS
VALVE
321
thermistor:
Plug out connector (CN-TH) from the
indoor unit PCB
Measure the resistance of the indoor
heat exchanger temperature thermistor
pipe temperature thermistor matches the
value specified in its characteristic chart?
or wrongly connected between discharge
and suction tube
thermistor
Replace the indoor pipe temperature
thermistor
(not energize)
connection
(4-way valve connector)
solenoid valve
continuity
the start of heating
supplied to CH-HOT at
Replace the 4-way valve
Replace Outdoor PCB
Measure continuity
of the coil
V-coil only
Replace
(4-way valve connector)
to solenoid valve
Replace
Outdoor PCB
Caution