125
20. Service Data
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.
20.1 Cool Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 27°C Dry Bulb/19°C Wet Bulb
- Unit setting: Standard piping length, forced cooling at 16°C, Hi fan
- Compressor frequency: Rated for cooling operation
- Piping length: 5m
- Voltage: 230V
20.1.1 CS-CZ25ZKE CU-CZ25ZKE
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
Low Pressure (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
14.60
14.80
15.00
15.20
15.40
15.60
15.80
16.00
16.20
16.40
16.60
16.80
15 20 25 30 35 40 45
15 20 25 30 35 40 45
15 20 25 30 35 40 45
1.50
1.70
1.90
2.10
2.30
2.50
2.70
2.90
0.95
1.00
1.05
1.10
1.15
1.20

Table of Contents