106
16. Push the holdfast to the left and lift up the evaporator.
18. Fan motor can be removed after the
removal of cross flow fan.
Reminder: To reinstall the fan motor, adjust
the fan motor connector to 45° towards you
before fixing control board.
17. Remove the cross flow fan from
the unit by
pulling it to the left and
downward.
Evaporator
Figure 9
Cross Flow Fan
Reminder: To reinstall the cross flow
fan, please ensure cross flow fan is
in line as shown in figure 10.
Figure 10