103
WARNING
18. Disassembly and Assembly Instructions
High Voltage are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding
with repair work. Failure to heed this caution may result in electric shocks.
18.1 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor
Removal Procedures
18.1.1 To Remove Front Grille
2. Remove 2 caps and 2 screws at the
bottom of discharge vane.
3. Hold both sides of the front grille and
remove it by pulling up and toward
you gently.
1. Lift to open the horizontal vane
gently.
Figure 1
18.1.2 To Remove Electronic Controller
4. Remove the Control Board
cover by releasing the hook.
Figure 2