58
14.4.1 Vertical Airflow
Operation Mode
Vane Angle (°)
1 2 3 4 5
Cooling, Fan
Auto
Usual (Ventilation) 10 ~ 40
Control with dew 10 ~ 40
Manual
Usual (Ventilation) 10 17.5 25 32.5 40
Control with dew 10 17.5 25 32.5 40
Dry
Auto
Usual 10 ~ 40
Control with dew 10 ~ 40
Manual
Usual 10 17.5 25 32.5 40
Control with dew 10 17.5 25 32.5 40
Heating
Manual Usual 10 21.2 32.5 43.8 55
Auto
A 10
B 43.8
C 21.2
1 Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner
is stopped using remote control, the vane will shift to close position.
2 Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above
and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control,
the vane will shift to close position.
Side View
Close position
Indoor Heat Exchanger
Temperature
Figure 2
140°C
0°
58°C
50°C
30°C
37°C
1
C
B
A
2
3
4
5
Figure 1
14.4.2 Horizontal Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.