ii. Auto Fan Speed
[Cooling, Dry]
According to room temperature and setting temperature, indoor fan speed is determined automatically.
The indoor fan will operate according to pattern below.
abc def gh
[1 pattern : 10 s]
ab
Higher
Fan
Speed
Medium
Lower
[Fan]
Indoor fan speed is fixed at predetermined speed.
[Heating]
According to indoor pipe temperature, automatic heating fan speed is determined as follows.
RPM Increased
RPM Maintain
RPM Reduced
OFF
Indoor Pipe Temp.
35
o
C
39
o
C
16
o
C
19
o
C
B. Feedback control
Immediately after the fan motor started, feedback control is performed once every second.
During fan motor on, if fan motor feedback
2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error
counter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 - fan
motor error is detected.
Operation stops and cannot on back.
14.3 Outdoor Fan Motor Operation
Outdoor fan motor is operated with 15 fan speed number of rotations. It starts when compressor starts operation and
it stops 30 seconds after compressor stops operation.
Compressor:
Fan Speed
30 sec
ON
ON
OFF
OFF
ON
ON
Outdoor Fan:

Other manuals for Panasonic CS-HZ25UKE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-HZ25UKE and is the answer not in the manual?

Panasonic CS-HZ25UKE Specifications

General IconGeneral
BrandPanasonic
ModelCS-HZ25UKE
CategoryAir Conditioner
LanguageEnglish

Related product manuals