30
12.2. Soft Dry Operation
• Soft Dry operation can be set using remote control.
• Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room.
• This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control.
• When operation begins, Soft Dry will be switched ON for a maximum 10 minutes, then Soft Dry operation will be turned OFF for
a minimum 6 minutes. After that, the Soft Dry operation will be ON and OFF based on the setting temperature as shown in below
figure.
• However after 3 minutes of compressor off, during Soft Dry OFF (within 6 minutes Soft Dry restart control), the indoor unit will
start to operate at normal Cooling mode if the intake temperature is higher than Cooling ON point.
12.2.1. Soft Dry Operation Time Diagram