12.8. Random Auto Restart Control
• If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
• It will start with previous operation mode and airflow direction.
• If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
• This Random Auto Restart Control is not available when Timer is set.
• This control can be omitted by open the circuit of JX02. (Refer printed circuit board indoor unit)
12.9. Remote Control Signal Receiving Sound
• Long beep sound will be heard when:
- Stopping the air conditioner using ON/OFF switch.
• Short beep sound will be heard for others setting.