31
12.3. Automatic Operation
• Automatic operation can be set using remote control.
• This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature.
• After judged the temperature, the operation mode is determined by referring to the below standard.
• Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting
temperature as shown in below table.
• The setting temperature for all the operations can be changed one level up or one level down from the standard temperature as
shown in below table by pressing on the temperature up or temperature down button at remote control.
• The operation mode judging temperature and standard setting temperature can be increased by 2°C permanently, by open the
circuit of JX03 at printed circuit board indoor unit.
12.4. Indoor Fan Speed Control
• Indoor Fan Speed can be set using remote control.
12.4.1. Fan Speed Rotation Chart
COOL/DRY CS-PC18HKF CS-PC24HKF
Hi 1400 1640
Me 1300 1460
Lo+ 1280 1400
Lo 1210 1310
Lo- 980 1100
S Lo 780 860