7.7. Delay ON Timer Control
When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
For Automatic mode, the indoor fan will operate at SLo speed for 20 seconds, 15 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
7.8. Remote Control Signal Receiving Sound
Long beep sound will be heard when:-
Stopping the Air Conditioner using ON/OFF switch.
Short beep sound will be heard for others.
To switch off the beep sound:-
Press the Automatic Operation Button continuously for 10 seconds or more (beep”“beep will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the Automatic Operation Button has been pressed the Automatic operation will be activated.
If you do not require this operation, you may change it by using the remote control.
20