28
7.2.3 CU-S18MKQ CU-S24MKQ
5
1
TERMINAL
BOARD
TO INDOOR UNIT
COMPRESSOR
SENSOR
COMPLETE
OUTDOOR AIR TEMP.
SENSOR (THERMISTOR)
PIPING TEMP.
SENSOR (THERMISTOR)
1
2
3
4
CN-TH1
(WHT)
t
0
t
0
AC-WHT
(WHT)
CN-ACFM
(WHT)
FG1
(GRN)
GRN
BLK
WHT
AC-BLK
(BLK)
COM3
(RED)
RED
GRY
L2-1
GRY
L2-0
REACTOR
RED
BLU
YLW
(RED)
FUSE1
T3.15A L250V
(BLU)
(YLW)
U
V
W
COMP. TEMPERATURE
SENSOR (THERMISTOR)
SENSOR
COMPLETE
1
3
CN-TANK
(WHT)
t
0
MS
3 ~
P
N
SWITCHING POWER
SUPPLY CIRCUIT
RECTIFICATION
CIRCUIT
FUSE2
T3.15A L250V
FAN MOTOR
CIRCUIT
FUSE3
(20A 250V)
RED (RED)
TRADE MARK
BLUE (BLU)
YELLOW (YLW)
COMP. TERMINAL
3
(RED)
2
(WHITE)
1
(BLACK)
NOISE FILTER
CIRCUIT
COMMUNICATION
CIRCUIT
PFC
CIRCUIT
ELECTRONIC CONTROLLER
YLW
RED
BLU
FAN MOTOR
M
1~
BLU
CAPACITOR
Resistance of Compressor Windings
MODEL CU-S18MKQ/CU-S24MKQ
CONNECTION 5RD132XBA21
U-V 1.897
U-W 1.907
V-W 1.882

Table of Contents

Other manuals for Panasonic CS-S12MKQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-S12MKQ and is the answer not in the manual?

Panasonic CS-S12MKQ Specifications

General IconGeneral
BrandPanasonic
ModelCS-S12MKQ
CategoryAir Conditioner
LanguageEnglish

Related product manuals