12.6 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)
Purpose
o To provide quiet cooling operation compare to normal operation.
Control condition
o Quiet operation start condition
When Quiet button at remote control is pressed Quiet INDICATOR illuminates.
o Quiet operation stop condition
When one of the following conditions is satisfied, quiet operation stops:
ECONAVI button is pressed.
Powerful button is pressed.
Mild Dry Cooling button is pressed.
Stop by OFF/ON button.
OFF Timer activates.
Quiet button is pressed again.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if ON timer activates, quiet operation maintains.
After off, when on back, quiet operation is not memorized.
Control content
o Fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of
Hi, Me, Lo for 3dB (more than 3dB for some models).
o Fan speed for quiet operation is -1 step from setting fan speed.
12.7 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft
Dry) than remote control setting temperature for 240 minutes and the fan speed will increase to achieve the
setting temperature quickly.
Powerful operation stops condition
o When one of the following condition is satisfied, powerful operation stops:
ECONAVI button is pressed.
Quiet button is pressed.
Mild Dry Cooling button is pressed.
Stop by OFF/ON button.
OFF Timer activates.
Powerful button is pressed again.
Powerful operation continue for 240 minutes.

Table of Contents

Other manuals for Panasonic CS-S12MKQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-S12MKQ and is the answer not in the manual?

Panasonic CS-S12MKQ Specifications

General IconGeneral
BrandPanasonic
ModelCS-S12MKQ
CategoryAir Conditioner
LanguageEnglish

Related product manuals