84
14.2 Remote Control Button
14.2.1 SET Button
• To check remote control transmission code and store the transmission code to EEPROM
o Press “Set” button continuously for 10 seconds by using pointer
o Press “Timer Set” button unit a “beep” sound is heard as confirmation of transmission code change.
• To change the air quality sensor:
o Press and release by using pointer
o Press the “Timer Decrement” button to select sensitivity:
1. Low sensitivity
2. Standard (Default)
3. Hi sensitivity
o Confirm setting by pressing “Timer Set” button, a “beep” sound will be heard. LCD returns to original display
after 2 seconds.
o LCD returns to original display if remote control does not operate for 30 seconds.
14.2.2 RESET (RC)
• To clear and restore the remote control setting to factory default.
o Press once to clear the memory
14.2.3 RESET (AC)
• To restore the unit’s setting to factory default.
o Press once to restore the unit’s setting
14.2.4 TIMER ▲
• To change indoor unit indicators’ intensity:
o Press continuously for 5 seconds.
14.2.5 TIMER ▼
• To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F)
o Press continuously for 10 seconds.