EasyManuals Logo

Panasonic CS-S12MKQ Service Manual

Panasonic CS-S12MKQ
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
49
10.1.7 Connect the Cable to the Indoor Unit
1 The inside and outside connection cable can be connected without removing the front grille.
2 Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1.5
mm
2
(1.0 ~ 1.5HP) or 4 x 2.5 mm
2
(2.0 ~ 2.5HP) flexible cord, type designation 245 IEC 57 or heavier cord.
Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise)
is too short.