EasyManua.ls Logo

Panasonic CS-S12MKQ

Panasonic CS-S12MKQ
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69
Airflow direction (Horizontal, Vertical) Control
o During any operation mode combines with Patrol operation, airflow direction follows respective operation
mode.
o During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is
pressed, no signal is sent to air conditioner, and no change on LCD display.
o During Patrol individual operation if e-ion stops, Airflow direction louver closed.
Indicator
o When Patrol is selected, patrol sensor indicator ON.
No Description BLUE ORANGE RED E-ION
1 When patrol function is not selected OFF OFF OFF -
2 During gas sensor error detection control OFF OFF Blinking OFF
3 During stop OFF OFF OFF OFF
4 2 minutes gas sensor initial stabilization time (Level 0) ON OFF OFF OFF
a. Dirtiness level 0* ON OFF OFF OFF
a. Dirtiness level 1 OFF ON OFF OFF
b. Dirtiness level 1* OFF ON OFF ON
5
During operation
During patrol
c. Dirtiness level 2 OFF OFF ON ON
Remote Control Receiving Sound
o Normal Operation Î Patrol Mode : Beep
o Patrol Mode Î Stop : Long Beep
o Patrol Mode Î Normal Operation : Beep
o Stop Î Patrol : Beep
Timer Control
o When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol
operation status.
o When ON timer activates during any operation, no change and carry on current operation.
o When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is
saved.
Power Failure Control
o During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation
resumes immediately.
o During combination operation, if power failure occurs, after power resumes combination operation resume
immediately.