Indoor CS-S24NKR CS-S28NKR
Model
Outdoor CU-S24NKR CU-S28NKR
Control
Device
Capillary Tube Expansion Valve
Refrigerant
Oil
cm
3
FV50S (800) FV50S (800)
Refrigeration
Cycle
Refrigerant
Type
g (oz) R410A, 1.58k (55.8) R410A, 1.77k (62.5)
Height
(I/D / O/D)
mm (inch) 290 (11-7/16) / 795 (31-5/16) 290 (11-7/16) / 795 (31-5/16)
Width
(I/D / O/D)
mm (inch) 1070 (42-5/32) / 875 (34-15/32) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth
(I/D / O/D)
mm (inch) 240 (9-15/32) / 320 (12-5/8) 240 (9-15/32) / 320 (12-5/8)
Weight
Net
(I/D / O/D)
kg (lb) 12 (26) / 56 (123) 12 (26) / 57 (126)
Pipe Diameter
(Liquid / Gas)
mm (inch) 6.35 (1/4) / 15.88 (5/8) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 30 (98.4) 3 (9.8) ~ 30 (98.4)
I/D & O/D Height different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 30 (0.3) 30 (0.3)
Piping
Length for Additional Gas m (ft) 10 (32.8) 10 (32.8)
Inner
Diameter
mm 16.7 16.7
Drain Hose
Length mm 650 650
Fin Material Aluminium (Pre coat) Aluminium (Pre coat)
Fin Type Slit Fin Slit Fin
Row × Stage
× FPI
2 × 15 × 21 2 × 15 × 21
Indoor Heat
Exchanger
Size
(W
× H × L)
mm
810 × 315 × 25.4
810 × 315 × 25.4
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Fin Type Slit Fin Slit Fin
Row × Stage
× FPI
2 × 36 × 17 2 × 36 × 17
Outdoor Heat
Exchanger
Size
(W
× H × L)
mm 25.4 × 756 × 905.9:885.9 25.4 × 756 × 905.9:885.9
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Outdoor Outdoor
Power Supply Cord A - -
Thermostat - -
Protection Device - -
DRY BULB WET BULB DRY BULB WET BULB
Maximum 32 23 32 23
Indoor Operation Range
Minimum 16 11 16 11
Maximum 46 26 46 26
Outdoor Operation Range
Minimum 5 4 16 11
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and