53
11.9 Auto Restart Control
• When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
• This type of control is not applicable during ON/OFF Timer setting.
• This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
11.10 Indication Panel
LED POWER TIMER QUIET/ECONOMY POWERFUL
Color Green Orange Orange Orange
Light ON Operation ON Timer Setting ON Quiet/Economy Mode ON Powerful Mode ON
Light OFF Operation OFF Timer Setting OFF Quiet/Economy Mode OFF Powerful Mode OFF
Note:
• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
• If TIMER LED blinking, there is an abnormality operation occurs.