51
11.4.2 Horizontal Airflow
Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below.
Operation Mode Vane angle (°)
Cooling and Soft dry 68 ~ 112
Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above:
Pattern 1 2 3 4 5
Airflow Direction
Patterns at Remote
Control
Vane Angle (°) 90 68 78 102 112
11.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)
Purpose
o To provide quiet cooling operation compare to normal operation.
Control condition
o Quiet operation start condition
When “QUIET” button at remote control is pressed twice.
QUIET/ECONOMY LED illuminates (low intensity).
o Quiet operation stop condition
When one of the following conditions is satisfied, quiet operation stops:
QUIET button is pressed again.
Stop by OFF/ON switch.
Timer “off” activates.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if timer “on” activates, quiet operation maintains.
After off, when on back, quiet operation is not memorised.
Control contents
o Fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB (some models more than 3dB).
o Fan speed for quiet operation is reduced from setting fan speed.
o Outdoor fan speed is change to QLo (S24NKR & S28NKR).
o Compressor frequency reduced.