8
Indoor CS-S18NKR
Model
Outdoor CU-S18NKR
Control
Device
Expansion Valve
Refrigerant
Oil
cm
3
FV50S (450)
Refrigeration
Cycle
Refrigerant
Type
g (oz) R410A, 1.31k (46.2)
Height
(I/D / O/D)
mm (inch) 290 (11-7/16) / 795 (31-5/16)
Width
(I/D / O/D)
mm (inch) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth
(I/D / O/D)
mm (inch) 240 (9-15/32) / 320 (12-5/8)
Weight
Net
(I/D / O/D)
kg (lb) 12 (26) / 50 (110)
Pipe Diameter
(Liquid / Gas)
mm (inch) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 5.0 (16.4)
Length range
(min – max)
m (ft) 3 (9.8) ~ 20 (65.6)
I/D & O/D Height
different
m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional
Gas
m (ft) 10 (32.8)
Inner
Diameter
mm 16.7
Drain Hose
Length mm 550
Fin Material Aluminium (Pre coat)
Fin Type Slit Fin
Row × Stage
× FPI
2 × 15 × 19
Indoor Heat
Exchanger
Size
(W
× H × L)
mm 810 × 315 × 25.4
Fin Material Aluminium (Blue coated)
Fin Type Slit Fin
Row × Stage
× FPI
2 × 36 × 17
Outdoor Heat
Exchanger
Size
(W
× H × L)
mm 25.4 × 756 × 847.9:827.9
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor
Power Supply Cord A -
Thermostat -
Protection Device -
DRY BULB WET BULB
Maximum 32 23
Indoor Operation Range
Minimum 16 11
Maximum 46 26
Outdoor Operation Range
Minimum 5 4
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB).