14.10 Quiet Operation (Heating)
A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
o When “FAN SPEED/QUIET” button at remote control is pressed continuously until QUIET will be shown
on remote control display.
b. Quiet operation stop condition
1 When one of the following conditions is satisfied, quiet operation stops:
a. POWERFUL button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. When FAN SPEED/QUIET button is pressed again and fan speed is change to Low.
e. Sleep mode timer delay OFF.
2 When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
4 During quiet operation, if timer “on” activates, quiet operation maintains.
5 After off, when on back, quiet operation is memorized.
C. Control contents
1 Fan speed is changed to QLo.
14.11 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft
Dry) or higher up to 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve the
setting temperature quickly.
14.12 nanoe
X Operation
Generate nanoe™ X (water wrapped ion particle) to moisturize skin, provide deodorization & sterilization effect.
nanoe™ X operation start condition
o During unit running at any operation mode, if nanoe™ X operation is activated, combination operation
(operation mode + nanoe™ X operation) starts.
o During unit is OFF, if nanoe™ X operation is activated, nanoe™ X individual operation starts.
nanoe™ X operation stop condition
o When OFF/ON button is pressed to stop the operation.
o When nanoe™ X button is pressed.
o When OFF Timer activates.
nanoe™ X operation pause condition
o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe™ X operation resume after
indoor fan restarts.
o When indoor intake temperature ≥ 35°C and ≤ 5°C. nanoe™ X operation resume after indoor intake
temperature < 35°C or ≥ 5°C continuously for 6 minutes.
Indoor fan control
o During any operation mode combines with nanoe™ X operation, fan speed follows respective operation
mode. However, nanoe™ X system enabled when fan speed ≥ 360 rpm to ensure proper negative ion
distribution, nanoe™ X system disabled when fan speed < 360 rpm.
o During nanoe™ X individual operation, fan speed follow remote control setting. Auto Fan Speed for
nanoe™ X individual operation is cooling medium fan. Powerful & Quiet is disabled during nanoe™ X.
Airflow direction control
o During any operation mode combines with nanoe™X operation, airflow direction follows respective operation
mode.
o During nanoe™ X individual operation, Air Swing follow remote control setting.