21
Model
Indoor CS-TZ71ZKEW
Outdoor CU-TZ71ZKE
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.98 7.10 8.40
BTU/h 3340 24200 28600
kcal/h 840 6110 7220
Running Current A – 9.80 –
Input Power W 420 2.20k 3.00k
Annual Consumption kWh – 1100 –
EER
W/W 2.33 3.23 2.80
BTU/hW 7.95 11.00 9.53
kcal/hW 2.00 2.78 2.41
ErP
Pdesign kW 7.1
SEER (W/W) 6.2
Annual
Consumption
kWh 401
Class A++
Power Factor % – 98 –
Indoor Noise (H / L / QLo)
Pressure Level
(dB(A)
47 / 38 / 35
Power Level dB 63 / – / –
Outdoor Noise (H / L)
Pressure Level
(dB(A)
52 / –
Power Level dB 66 / –
Heating
Capacity
kW 0.98 8.20 10.20
BTU/h 3340 28000 34800
kcal/h 840 7050 8770
Running Current A – 9.80 –
Input Power W 400 2.21k 3.10k
COP
W/W 2.45 3.71 3.29
BTU/hW 8.35 12.67 11.23
kcal/hW 2.10 3.19 2.83
ErP
Pdesign kW 5.5
Tbivalent °C -10
SCOP (W/W) 4.1
Annual
Consumption
kWh 1878
Class A+
Power Factor % – 98 –
Indoor Noise (H / L / QLo)
Pressure Level
(dB(A)
47 / 38 / 35
Power Level dB 63 / – / –
Outdoor Noise (H / L)
Pressure Level
(dB(A)
54 / –
Power Level dB 68 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 7.39 / 2.74k / 2.70
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 6.31 / 2.60k / 2.43
Max Current (A) / Max Input Power (W) 14.7 / 3.28k
Starting Current (A) 9.80