107
18.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 20°C DryBulb/ -°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 230V
18.2.1 CS/CU-PE9RKE CS/CU-UE9RKE
Outlet Air (°C)Outlet Air (°C)
Outdoor Air Temperature (°C)
High Pressure (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
2.60
2.80
3.20
3.60
4.00
4.40
3.00
3.40
3.80
4.20
4.80
4.60
1.20
1.40
1.60
1.80
2.00
2.20
2.40
2.60
3.00
2.80
20
24
28
32
36
44
40
-12 -2 8 18
-12 -2 8 18
-12 -2 8 18