15 CAPACITY AND POWER CONSUMPTION
15.1. HEATING PERFORMANCE
Model Heating capacities are based on conditions below.
CS-W34BB4P
1 phase, 50Hz, 230V
Indoor temperature 20°C D.B.T.
Outdoor temperature 7°CD.B.6°C W.B.T.
Standard air volume 24m
3
/min
CU-W34BBP5
Heating capacity 11.2 kW
Inlet Air Outdoor Temperature(°C W.B.T.)
Air Volume (m
3
/min) Entering Air
D.B.T. (°C)
-6°C 0°C 6°C 12°C
H.C. IPT H.C. IPT H.C. IPT H.C. IPT
15 8.18 2.85 9.80 3.26 11.8 3.87 13.7 4.56
23m
3
/min 20 7.73 3.01 9.24 3.46 11.2 4.07 13.4 4.72
25 7.28 3.17 8.74 3.66 10.6 4.27 12.9 4.92