Troubleshooting
The following symptoms do not indicate malfunction.
Symptom Cause
POWER indicator blinks before the unit is
switched on.
This is a preliminary step in preparation for the
operation when the ON timer has been set.
When ON Timer is set, the unit may start earlier (up
to 35 minutes) before the actual set time in order to
achieve the desired temperature on time.
POWER indicator blinks during HEAT mode
with no warm air supply (and ap is closed).
The unit is in defrost mode (and AIR SWING is set to
AUTO).
POWER indicator blinks and stops when
operate COOL/DRY mode.
The system has locked to operate in HEAT mode only.
TIMER indicator is always on. The timer setting repeats daily once set.
Operation is delayed a few minutes after
restarting.
The delay is a protection to the unit’s compressor.
Cooling/heating capacity reduced during the
lowest fan speed setting.
The low fan speed is low noise priority operation, so
cooling/heating capacity may be reduced (depending
on the condition). Increase the Fan Speed to increase
the capacity.
Indoor fan stops occasionally during heating
operation.
To avoid unintended cooling effect.
Indoor fan stops occasionally during automatic
fan speed setting.
This helps to remove the surrounding odour.
Air ow continues even after operation has
stopped.
Extraction of remaining heat from the indoor unit
(maximum 30 seconds).
The room has a peculiar odour. This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Cracking sound during operation. Changes of temperature caused the expansion/
contraction of the unit.
Water owing sound during operation. Refrigerant ow inside the unit.
Mist emerges from indoor unit. Condensation effect due to cooling process.
Outdoor unit emits water/steam. Condensation or evaporation occurs on pipes.
Discoloration of some plastic parts. Discoloration is subject to material types used in plastic
parts, accelerated when exposed to heat, sun light, UV
light or environmental factor.
Wireless LAN LED stays ON during unit turn
OFF.
Unit’s LAN connection with the router is activated.
Check the following before calling for servicing.
Symptom Check
Operation in HEAT/COOL mode is not working
ef ciently.
Set the temperature correctly.
Close all doors and windows.
Clean or replace the lters.
Clear any obstruction at the air inlet and air outlet
vents.
Noisy during operation. Check if the unit has been installed at an incline.
Close the front panel properly.
Remote control does not work.
(Display is dim or transmission signal is weak.)
Insert the batteries correctly.
Replace weak batteries.
The unit does not work. Check if the circuit breaker is tripped.
Check if timers have been set.
The unit does not receive the signal from the
remote control.
Make sure the receiver is not obstructed.
• Certain uorescent lights may interfere with signal
transmitter. Please consult authorised dealer.

Other manuals for Panasonic CS-Z25VKEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-Z25VKEW and is the answer not in the manual?

Panasonic CS-Z25VKEW Specifications

General IconGeneral
AC input voltage230 V
Design load (cooling)2.5 kW
Annual energy consumption (cooling)103 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.7 kW
Energy efficiency class (heating) (Colder heating season)-
Energy efficiency class (heating) (Average heating season)A+++
Annual energy consumption (heating) (Average heating season)741 kWh
TypeAir conditioner indoor unit
Multi-splitNo
Product colorWhite
Dehumidifying capacity1.5 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3200 W
Cooling capacity in watts (min)850 W
Heating capacity in watts (max)5000 W
Heating capacity in watts (min)800 W
Cooling capacity in watts (nominal)2500 W
Cooling energy efficiency (EER, W/W)4.81
Heating energy efficiency (COP, W/W)4.79
Seasonal efficiency rating (cooling) (SEER)8.5
Seasonal efficiency rating (heating) (SCOP)5.1
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3400 W
Indoor unit typeWall-mountable
Indoor unit depth194 mm
Indoor unit width919 mm
Indoor unit height295 mm
Indoor unit weight10000 g
Indoor units quantity1
Cooling airflow (indoor unit)612 m³/h
Heating airflow (indoor unit)672 m³/h
Indoor unit sound power level55 dB
Indoor unit noise level (low speed)19 dB
Indoor unit noise level (high speed)39 dB
Wi-FiYes