14
Model
Indoor CS-Z50UFEAW
Outdoor CU-Z50UBEA
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.90 5.00 5.70
BTU/h 3070 17100 19400
kcal/h 770 4300 4900
Running Current A – 6.20 –
Input Power W 255 1.39k 1.81k
Annual Consumption kWh – 695 –
EER
W/W 3.53 3.60 3.15
BTU/hW 12.04 12.30 10.72
Kcal/hW 3.02 3.09 2.71
ErP
Pdesign kW 5.0
SEER (W/W) 6.7
Annual
Consumption
kWh 261
Class A++
Power Factor % – 97 –
Indoor Noise (H / L / QLo)
dB-A 44 / 31 / 27
Power Level dB 60 / – / –
Outdoor Noise (H / L / QLo)
dB-A 48 / – / –
Power Level dB 63 / – / –
Heating
Capacity
kW 0.90 5.80 8.10
BTU/h 3070 19800 27600
kcal/h 770 4990 6970
Running Current A – 7.00 –
Input Power W 260 1.55k 2.60k
COP
W/W 3.46 3.74 3.12
BTU/hW 11.81 12.77 10.62
kcal/hW 2.96 3.22 2.68
ErP
Pdesign kW 4.4
Tbivalent °C -10
SCOP (W/W) 4.3
Annual
Consumption
kWh 1433
Class A+
Power Factor % – 96 –
Indoor Noise (H / L / QLo)
dB-A 46 / 33 / 29
Power Level dB 62 / – / –
Outdoor Noise (H / L / QLo)
dB-A 48 / – / –
Power Level dB 63 / – / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 5.87 / 2.30k / 2.55
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 5.03 / 2.06k / 2.44
Max Current (A) / Max Input Power (W) 11.4 / 2.60k
Starting Current (A) 7.00