3.2. Duct Type
Model Unit CS-ME10DD3EG CS-E15DD3EW CS-E18DD3EW
Item Duct Type
Power Source Outdoor power Single 230V 50Hz
Air Volume Cooling m
3
/min
(cfm)
High: 7.0
(250)
High: 7.8
(280)
High: 10.3
(360)
Heating m
3
/min
(cfm)
High: 8.9
(310)
High: 12.6
(440)
Noise Level Cooling
(Power)
dB(A)
(dB)
High: 31 (47)
Low: 27
High: 33 (49)
Low: 27
High: 41 (57)
Low: 30
Heating
(Power)
dB(A)
(dB)
High: 35 (51)
Low: 27
High: 35 (51)
Low: 28
High: 41 (57)
Low: 32
Moisture Removal L/h
(Pint/h)
1.6
(3.4)
2.3
(4.9)
2.8
(5.9)
Refrigeration
Piping
Connection Liquid mm (inch) 6.35 (1/4”)
Gas mm (inch) 9.52 (3/8”) 12.7 (1/2”)
Type of Indoor / Outdoor connecting cable mm 4 × 1.5 mm
2
flexible cord, type designation 245 IEC 57 (H05RN-F)
Drain
Hose
Inner diameter mm VP20
Length m 0.255
Dimensions Height mm (inch) 235 (9 - 1/4) 285 (11 - 7/32)
Width mm (inch) 750 (29 - 17/32)
Depth mm (inch) 370 (14 - 9/16)
Net Weight lb (kg) 17 (37) 18 (40)
Air Circulation Type Sirocco Fan
Motor Type Transistor 8-poles
Output W 30
Heat Exchanger Plate fin configuration, forced draft
Row / Stage 2/8 3/12
Thermostat Electronic Control
Protection Device Electronic Control
Air Filter
Specifications are subject to change without notice for further improvement.