EasyManua.ls Logo

Panasonic CU-3E18EBE - Page 41

Panasonic CU-3E18EBE
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Notes:
8.1.1.7. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Soft Dry, Fan]
Remote Control O O O O O
Tab (rpm) PSHi SHi Hi Me+ Me Me- Lo Lo- SLo SSLo
CS-ME7DKEG 1320 1320 1280 1210 1040 970 920 860 720 710
CS-E9DKEW 1320 1320 1280 1210 1040 970 920 860 720 710
CS-E12DKEW 1460 1460 1420 1320 1220 1120 1020 950 720 710
CS-E15DKEW 1500 1500 1460 1350 1240 1130 1020 950 720 710
CS-E18DKEW 1540 1540 1450 1340 1240 1140 1040 980 770 640
[Heating]
Remote Control O O O O O
Tab (rpm) PSHi SSHi SHi Me+ Me Me- Lo Lo- SLo SSLo
CS-ME7DKEG 1440 1440 1400 1290 1170 1060 950 870 720 710
CS-E9DKEW 1440 1440 1400 1290 1170 1060 950 870 720 710
CS-E12DKEW 1540 1540 1500 1400 1290 1180 1070 990 720 710
CS-E15DKEW 1570 1570 1560 1430 1310 1190 1070 990 720 710
CS-E18DKEW 1640 1640 1580 1470 1350 1230 1110 1040 400 300
1. Refer to the CS-ME7DKEG column for CS-ME7DKDG.
2. Refer to the CS-E9DKEW column for CS-E9DKDW.
3. Refer to the CS-E12DKEW column for CS-E12DKDW.
4. Refer to the CS-E15DKEW column for CS-E15DKDW.
5. Refer to the CS-E18DKEW column for CS-E18DKDW.
41

Other manuals for Panasonic CU-3E18EBE

Related product manuals