8.4.1.7. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Soft Dry, Fan]
Remote Control O O O O O
Tab (rpm) PSHi SHi Hi Me+ Me Me- Lo Lo- SLo SSLo
CS-E15DB4EW 600 600 560 520 480 440 400 350 310 200
CS-E18DB4EW 640 640 590 550 510 470 430 390 350 200
[Heating]
Remote Control O O O O O
Tab (rpm) PSHi SHI Hi Me+ Me Me- Lo Lo- SLo SSLo
CS-E15DB4EW 650 650 600 570 540 510 480 460 300 300
CS-E18DB4EW 690 690 640 600 570 530 490 470 320 300