268
Heating Characteristic
[Condition] Room temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping length: 5.0 m
Voltage: 230V, 50Hz
A) Indoor unit capacity: Heating (2.0), CS-Z20TKEW
Outdoor Air Temperature (°C)
Indoor Discharge Ai
Temperature (°C)
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
30.000
31.500
33.000
34.500
36.000
37.500
39.000
40.500
42.000
43.500
45.000
Outdoor Air Temperature (°C)
Current
(A)
-16-14-12-10-8-6-4-2024681012
6.400
6.560
6.720
6.880
7.040
7.200
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa)
2.800
2.850
2.900
2.950
3.000
3.050
3.100
3.150
3.200
3.250
3.300
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
www.ampair.co.uk | sales@ampair.co.uk