279
Heating Characteristic
[Condition] Room temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping length: 5.0 m
Voltage: 230V, 50Hz
B) Indoor unit capacity: Heating (2.5), CS-Z25TKEW
Outdoor Air Temperature (°C)
Indoor Discharge Ai
Temperature (°C)
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
32.000
33.700
35.400
37.100
38.800
40.500
42.200
43.900
45.600
47.300
49.000
Outdoor Air Temperature (°C)
Current
(A)
-16-14-12-10-8-6-4-2024681012
6.200
6.520
6.840
7.160
7.480
7.800
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa)
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
2.500
2.590
2.680
2.770
2.860
2.950
3.040
3.130
3.220
3.310
3.400
www.ampair.co.uk | sales@ampair.co.uk