o nanoe-G breakdown error
Judgment method
Hi-feedback voltage (at microcontroller) supplied to the nanoe-G system when nanoe-G operation is
OFF; nanoe-G breakdown error show immediately.
It is due to indoor PCB or nanoe-G high voltage power supply damage.
Operations except nanoe-G continue. Both Timer indicator and nanoe-G indicator blink.
Troubleshooting method
Press nanoe-G button or OFF/ON button to stop the operation.
Change nanoe-G high voltage power supply or main PCB.
When Lo-feedback voltage supplied to nanoe-G system during nanoe-G operation ON, nanoe-G
indicator and Timer indicator stop blinking.