4. Indoor unit installation
Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the rear top
of the indoor unit with the upper edge of the installation
plate.)
Ensure the hooks are properly seated on the installation
plate by moving it left and right.
5. Connecting the piping to the indoor unit
Align the center of the piping and sufficiently tighten the
flare nut with fingers.
Finally, tighten the flare nut with torque wrench until the
wrench clicks.
When tightening the flare nut with torque wrench,
ensure the direction for tightening follows arrow on the
wrench.
Model Piping side Torque
CS-SA9CKP/
CU-SACKP5
Liquid side 1/4" 18N.m
CS-SA12CKP5/
CU-SA12CKP5
CS-SA9CKP/
CU-SACKP5
Gas side 3/8" 42N.m
CS-SA12CKP5/
CU-SA12CKP5
Gas side 1/2" 55N.m
6. Set the piping and the connecting cable to the back of
chassis with the clamping cover.
7. Tape the piping, drain hose and connecting cable.