Unit CS-SA12CKP CU-SA12CKP5
Air Circulation Type Cross-flow Fan Propeller fan
Motor Type Induction (4 pole) Induction (6 pole)
Input W 58.6
Rate Output W 13 20
Fan Speed Low rpm 980
Medium rpm 1090
High rpm 1200 750
Heat Exchanger Discription Evaporator Condenser
Tube Material copper copper
Fin Type slot type Corrugation type
Rows / Stage (Plate fin configuration, forced draft)
2×15 1×20
FPI 18 18
Dimensions mm 610 × 315 × 25.4 706.2 × 482.6 × 22
Refrigerant Control Device Capillary Tube
Refrigeration Oil (c.c) SUNISO 4GDID or ATMOS M60
(350)
Refrigerant (R-22) g 940
Thermostat Electronic Control
Protection Device Overload Protector
Capillary Length mm Cooling: 470, Heating: 1160
Circulation L/min Cooling: 13.4, Heating: 4.5
Inner dia mm Cooling: 1.5, Heating: 1.2
Air Filter P.P Honeycomb
Refrigerant Circulation Control Device Capillary
Compressor Capacitor µFV 30µF, 370V
Fan Motor Capacitor µFV 1.5µF, 400V 1.8µF, 400V
Specifications are subject to change without notice for further improvement
The amount of refrigerant (60g) for air purging not included