26
9.4 Indoor Fan Speed Control
Indoor fan speed can be set using remote control.
9.4.1 Fan Speed rotation Chart
speed
Model
Hi Me Lo Slo
CS-YC9 1080 920 750 500
CS-YC12 1140 1000 820 500
9.4.2 Automatic Fan Speed Control
z When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in
the table.
Shi Hi Me Lo Lo- SLo SSLo
Auto o o o
Cooling
Manual o o o
Auto o o
Soft Dry
Area
Manual o o
z Auto Fan Speed during cooling operation:-
1. At the beginning of each compressor starts operation, indoor fan speed increases gradually for deodorizing
purpose.
2. Indoor fan will rotate alternately between off and on as shown in below diagram.
*1. Fan speed will be at Hi till the compressors ceases when set temperature is reached.
*2. Fan Speed will be at Me when the compressor restarts.
z Auto Fan Speed during soft Dry operation.
1. Indoor fan will rotate alternately between OFF and Lo-.
2. At the beginning of each compressor starts operation, indoor fan will increase fan speed gradually for deodorizing
purpose.